Power Transmission & Distribution Cable Accessories
Cable joints, terminations, busbar insulation, bushing protection and overhead line covers for transmission and distribution utilities — from the substation bay to the overhead conductor, tested to ANSI C37.20.2 where a busbar or switchgear part is involved.
Products in this illustration (8)
- Three-core Cable Termination
Collector and feeder cable connections.
- Straight-through Cable Joint
Underground cable connections.
- Screened Separable Connectors
Cable connection to equipment bushings.
- Busbar Insulation
Insulates live bars inside switchgear.
- Bushing Connection Covers
Protects exposed terminal connections.
- Silicone Line Cover
Local conductor protection against wildlife.
- Wraparound Repair Sleeve
Repairs an outer cable jacket.
- Pole Protection Sleeve
Protects the pole near ground level.
Product range
Products for this industry (26)
Heat Shrinkable Cable Joints
Heat Shrinkable Cable Terminations
Screened Separable Connectors
Overhead Line Cover - Polyolefin
Overhead Line Tube - Polyolefin
Overhead Line Cover - Silicone - Inter-locking
Overhead Line Cover - Silicone - Self-locking
Wildlife and Asset Protection Products / Insulation Enhancement Products
High Voltage Wraparound Creepage Extenders
Bus/Bushing Connection Insulating Covers (Reusable)
Heat Shrink Pole Protection Sleeve
Heat Shrink Busbar Sleeves - up to 66kV
Show 14 more products
Heat Shrink Tape
Terminal Protector
Heat Shrink Wrap Around Sleeve
Heat Shrink Cable Repair Sleeve
Heat Shrink Low Voltage Cable Breakouts
Cold Shrink Breakout
Heat Shrink Cable End Caps
Cold Shrink End Cap
Heat Shrink Live End Caps
Heat Shrink Medium/Heavy Wall Tubes
Cold Shrink Tubing
Bushing Boot
Heat Shrink Right Angle / Straight Boot
Heat Shrink Pole Cap
Overview
A design team with over two decades of practical experience in cable jointing and terminating MV cables. Heat Shrink Joints for PVC/PILC/XLPE/EPR low and medium voltage power cable up to 66 kV Class, upheld to the most stringent national and international standards. CLASS 1 Terminations make the terminating length between wire and contact point tamper-proof against environmental factors.
Screened Separable Connectors connect single- and three-core polymeric cable to switchgear, transformers and RMUs on type "C" bushings — 630A to 24 kV standard, 630/1250A to 36 kV in the extended range — in EPDM rubber with a touch-proof outer screen connected to earth.
Read the full overview
Heat Shrink Busbar Sleeve insulates busbar systems up to 36 kV and reduces air clearance, meeting ANSI C37.20.2 for MV switchgear; a separate extra-heavy-wall series (GEHB) extends that to 66 kV. Heat Shrink Tape insulates busbar connections where tubing can't be used.
Overhead Line Cover and Overhead Line Tube give retrofit insulation on distribution conductors — UV-resistant polyolefin, Phase-to-Phase and Phase-to-Ground protection against trees and wildlife. Silicone Interlocking and Silicone Overhead Line Covers add non-tracking silicone for field installation over bare conductors, insulation up to 33 kV and 765 kV respectively.
Creepage Extenders seal to porcelain or glass insulators to drive leakage current around the skirt edge, reducing pollution-flashover risk. Bus Connection Insulating Covers (GPFIC) protect energised busbar, standoff insulators, capacitors and transformer bushings from bird and animal contact.
Terminal Protector gives phase-to-phase-to-earth insulation in compact enclosures — motor terminal boxes, RMUs, distribution transformers. Bushing Boot insulates the cable-to-bushing connection up to 24 kV against flashover from humidity, rodents and surge impulse. Pole Cap protects the top of a wooden pole from water and moisture ingress.
Heat Shrink Cable End Caps and Cold Shrink End Caps give a tamper-proof, moisture-tight seal to cable ends, and Live End Caps seal the ends of live cables. Heat Shrink Low Voltage Cable Breakouts and Cold Shrink Breakouts seal the crutch of 2–7 core cable up to 3.3 kV. Medium and heavy wall tube gives environmental and mechanical protection to LV and MV cable joints, and Heat Shrink Cable Repair Sleeve repairs a damaged jacket; the mastic-coated Wrap Around Sleeve seals and corrosion-protects pipeline joints and other substrates.
Applications Served
- Overhead line insulation for T&D distribution networks
- Busbar insulation up to 66 kV inside substation switchgear
- Cable-to-bushing and cable-to-RMU connections up to 36 kV
- Wildlife/asset protection against flashover from birds and animals
What Gala Offers
- Heat shrink cable joints and CLASS 1 terminations up to 66 kV Class
- Screened separable connectors: 630A to 24 kV standard, 630/1250A to 36 kV extended range, EPDM rubber
- Heat shrink busbar sleeve up to 36 kV (66 kV in the extra-heavy-wall GEHB series), meets ANSI C37.20.2
- UV-resistant polyolefin and non-tracking silicone overhead line covers/tubes
- Terminal protector for compact panels (motor terminal boxes, RMUs, distribution transformers)
- Bushing boot for cable-to-bushing insulation up to 24 kV