Manufacturing since 1979 · Exporting to 100+ countries

Send us your query

Fields marked with an asterisk are required.

Your enquiry details

Your local time. Leave both blank for any time.

Wildlife & Asset Protection application illustration showing silicone line cover, polyolefin line cover, creepage extenders, reusable bushing covers, busbar sleeves, heat shrink tape, bushing boots, pole protection sleeve.
Select the image to inspect the numbered details. Product specifications are linked below.

Wildlife Protection & Insulation Enhancement Products

Retrofit insulation covers, creepage extenders and busbar sleeves that stop outages caused by bird and animal contact — the risk is bare busbars, conductors and connections that can accidentally bridge phase or phase-to-ground.

Products in this illustration (8)
  1. Silicone Line Cover

    Protects exposed conductor jumpers.

  2. Polyolefin Line Cover

    Retrofit insulation on selected bare lines.

  3. Creepage Extenders

    Extends the surface leakage path.

  4. Reusable Bushing Covers

    Covers exposed terminal connections.

  5. Busbar Sleeves

    Insulates separate live busbars.

  6. Heat Shrink Tape

    Insulates irregular busbar joints.

  7. Bushing Boots

    Insulates cable-to-bushing interfaces.

  8. Pole Protection Sleeve

    Protects a metal pole at ground level.

Wildlife Protection & Insulation Enhancement

Download PNG
Wildlife & Asset Protection application illustration showing silicone line cover, polyolefin line cover, creepage extenders, reusable bushing covers, busbar sleeves, heat shrink tape, bushing boots, pole protection sleeve.

Select “Actual size” to read small details.

Product range

Products for this industry (15)

Show 3 more products

Overview

Bare busbars, conductors and connections risk birds, animals, vegetation and airborne debris bridging phase-to-phase or phase-to-earth clearances — causing outages, equipment damage and, in some cases, electrocuting the animal. Gala's pre-moulded protection covers, heat shrinkable tubes, tapes and sheets retrofit insulation onto that bare metalwork.

Creepage extenders seal to porcelain or glass insulators, adding creepage distance and reducing electric stress by driving leakage current around the extender's skirt edge.

Read the full overview

GPFIC bus/bushing connection covers are UV-stable, field-trimmable at the entry/exit holes, and reusable for later maintenance — sized for busbar connections, standoff insulators, capacitors and transformer bushings.

Overhead line covers and tubes field-install over bare conductors for phase-to-phase and phase-to-ground protection from bird and animal contact: UV-resistant polyolefin covers and tubes, GSIOC non-tracking silicone interlocking covers to 33 kV, and GSOC self-locking silicone covers for insulation enhancement to 765 kV.

The heat shrink busbar sleeve, in cross-linked polyolefin, insulates busbar systems up to 36 kV, reduces air clearance and guards against accidental flashover — to ANSI C37.20.2 for MV switchgear application up to 36 kV; a separate extra-heavy-wall series (GEHB) extends that to 66 kV. Heat Shrink Tape insulates busbar connections where tubing cannot be used.

Bushing Boots are non-tracking elastomeric boots that fit over switchgear bushings, insulating right-angled or straight connections up to 24 kV and guarding against flashover or surges in switchgear and transformer boxes.

Screened Separable Connectors connect single and three-core polymeric cable to MV switchgear, transformers and RMUs via type "C" bushings, specified for 630 A up to 36 kV. Built from highly modified EPDM rubber with a touch-proof, earthed outer screen.

Heat Shrink Pole Protection Sleeve, in cross-linked polyolefin, seals a wooden pole's ground-line area against decay for long-term pole maintenance.

Applications Served

  • Overhead distribution line protection from bird/animal contact
  • Busbar and bushing flashover protection inside switchgear
  • Wooden pole ground-line decay protection

What Gala Offers

  • Pre-moulded protection covers, heat shrinkable tubes, tapes and sheets as a retrofit solution
  • Creepage extenders seal to porcelain or glass insulators to drive leakage current around the skirt edge
  • UV-stable reusable bus/bushing connection insulating covers (GPFIC)
  • UV-resistant polyolefin and non-tracking silicone overhead line covers/tubes (GSIOC to 33 kV, GSOC to 765 kV)
  • Heat shrink busbar sleeve up to 36 kV (66 kV in the extra-heavy-wall GEHB series), meets ANSI C37.20.2
  • Non-tracking elastomeric bushing boots for right-angle/straight bushing connections up to 24 kV
  • Screened separable connectors for type "C" bushings, 630 A up to 36 kV

Need this for a live project?