GSC Flame Retardant Thin Wall Heat Shrink Tube

GSC is a halogen-free, flame-retardant thin wall heat shrink tube for light-duty wire harnessing and busbar insulation; GSC/YG adds yellow/green striping for ground-lead identification.

  • Insulation up to 3.3 kV
  • MIL-I-23053/5 Class 2 & 3
  • UL 224 (File No. E328193), 125°C VW-1
  • CSA C22.2

Choose a size

Selection Chart

GSC thin wall tube selection chart, 2:1 — all dimensions in mm
Part number / sizeSupplied I.D.(mm)Recovered I.D.(mm)Recovered wall thickness(mm)Spools(m / spool)Cut length 1.2 m(per box)
GSC 1.0/0.51.00.50.28400600
GSC 1.5/0.751.50.750.32400600
GSC 2.0/1.02.01.00.35400600
GSC 2.5/1.22.51.20.44400600
GSC 3.0/1.53.01.50.44400500
GSC 4.0/2.04.02.00.44400250
GSC 5.0/2.55.02.50.56200250
GSC 6.0/3.06.03.00.56200200
GSC 7.0/3.57.03.50.56100200
GSC 8.0/4.08.04.00.56100175
GSC 10.0/5.010.05.00.56100150
GSC 12.7/6.3512.76.350.56100120
GSC 14.0/7.014.07.00.69100100
GSC 16.0/8.016.08.00.69100100
GSC 18.0/9.018.09.00.6910080
GSC 20.0/10.020.010.00.7810065
GSC 25.0/12.525.012.50.785040
GSC 30.0/15.030.015.00.875030
GSC 40.0/20.040.020.00.975020
GSC 50.0/25.050.025.00.972515
GSC 60.0/30.060.030.00.962510
GSC 70.0/35.070.035.01.102510
GSC 80.0/40.080.040.01.272510
GSC 100/50.0100.050.01.17255

Code for yellow/green striped tubes: GSC/YG. Standard colours: black, white, yellow, red, blue, green and yellow/green. Source: GALA GSC Thin Wall Flame Retardant Tube catalogue sheet, Issue 2, February 2026.

Material properties

Technical Specification

GSC technical specification
PropertiesValueStandard
Physical
Tensile Strength9 N/mm² (Mpa) (min.)ASTM D638
Ultimate Elongation300% (min.)ASTM D638
Water Absorption0.15% (max.)ASTM D570
Specific Gravity1.4ASTM D792
Longitudinal Change-10% (max.)ASTM D638
Thermal
Operating Temperature-55 °C to +125 °CIEC 216
Heat Shock (250 °C for 4 hrs.)No dripping, cracking or flowing
Low Temperature Flexibility (-55 °C for 4 hrs.)No CrackingASTM D2671
FlammabilityPassUL224 VW-1
Chemical
Fungus ResistanceInertMIL-1-7444
Copper CorrosionGoodASTM D2671B
Chemical ResistanceGoodASTM D2671
Electrical
Dielectric Strength>20kV/mm.ASTM D2671
Di-electric Constant3.0 (max.)ASTM D150
Volume Resistivity1 x 10¹³ Ohm.cm (min.)ASTM D257

Source: GALA GSC Thin Wall Flame Retardant Tube catalogue sheet, Issue 2, February 2026.

GSC is a halogen-free, flame-retardant thin-wall tube for light-duty wire harnessing and busbar insulation; the GSC/YG variant adds a yellow/green stripe for instant ground-lead identification.

Covered on this page

  • Thin Wall Tubes
  • GSC: Flame Retardant Tube
  • GSC Series :
  • GSC/YG Series :

Features & Benefits

  • Halogen-free, flame retardant and self-extinguishing
  • 2:1 shrink ratio
  • Insulation up to 3.3 kV
  • UV stabilised, RoHS compliant
  • Seven standard colours including a yellow/green striped ground-lead variant
  • GSC 1.0/0.5 to GSC 100/50.0 size range

Applications

  • Light-duty wire harnessing for electrical and electronic equipment
  • In-line component insulation and protection
  • Strain relief for wire connections
  • Busbar insulation for switchgear
  • Wire, cable, terminal and component colour coding
  • Ground-lead identification (GSC/YG)

Standards & Compliance

  • MIL-I-23053/5 Class 2 & 3
  • UL 224 (File No. E328193), 125°C VW-1
  • CSA C22.2

FAQs

Frequently Asked Questions

What is the GSC Flame Retardant Thin Wall Heat Shrink Tube used for?

It is used for:

  • Light-duty wire harnessing for electrical and electronic equipment
  • In-line component insulation and protection
  • Strain relief for wire connections
  • Busbar insulation for switchgear
  • Wire, cable, terminal and component colour coding
  • Ground-lead identification (GSC/YG)
How do I choose the right size?

A heat-shrink part is chosen by two diameters. As supplied (Supplied I.D. (mm)) it must open wider than the largest thing it has to slide over; after shrinking (Recovered I.D. (mm)) it must close smaller than the smallest thing it has to grip. Measure both on your cable or busbar and pick the first code in the selection chart that satisfies both.

How is it installed?

Clean and degrease the surface, position the part, then shrink it with a gas torch or a hot-air gun: keep the heat moving round it with a smooth, brushing motion so it recovers evenly without scorching. Start at one end and work steadily along to the other.

Which standards and test methods are quoted for it?

These, with the values in the Technical Specification on this page:

  • MIL-I-23053/5 Class 2 & 3
  • UL 224 (File No. E328193), 125°C VW-1
  • CSA C22.2
Where can I download the datasheet?

From the "Download datasheet" button at the top of this page, or here:

Thin wall GSC 3X.pdf

Can I get a quote, a sample or a size that is not listed?

Send your cable details, quantity and application with the "Request a Quote or Sample" form at the foot of this page. For a size or variant that is not in the chart, describe what you need there, or use Technical support at the top of the page, and the technical team will confirm what can be supplied.

  • 47+

    Years manufacturing

  • 100+

    Countries served

  • 140

    Products in range

  • ISO 9001:2015

    Certified & tested

Need GSC Flame Retardant Thin Wall Heat Shrink Tube for a live project?

Send us your requirement, call the plant directly, or take the datasheet with you.

Request a Quote or Sample

Tell us what you need — our technical team will get back to you.

Fields marked with an asterisk are required.

Your enquiry details